Esperanto
Shqiptare
Euskara
Zulu
Latinus
Cymraeg
தமிழ்
Slovak
Slovak
Afrikaans
Primary system
→ For all major DC fan coil brands on the market
→ For heat pump system, simultaneous control of AC/DC fan coil and floor heating
→ DC fan with 0~10V automatic speed control and 5-speed manual speed control
→ Dry contact & Modbus 485, remote & voice control, APP timing & scene setting, temperature & humidity display
→ Zone control: according to the nature of the use of different rooms and user habits to set different temperatures to achieve independent constant temperature and humidity control with a single room unit
→ The air conditioning and floor heating line is the same as the traditional temperature control panel, which can be directly used for new installation & upgrading of old systems
Radiant floor system
→ For heat pump system, simultaneous control of AC/DC fan coils & ground radiation
→ Dry contact & Modbus 485, remote & voice control, APP timing & scene set control, temperature & humidity display
→ Two cooling modes (floor cooling + fan coil, fan coil); three heating modes (floor heating, floor heating + fan coil, fan coil)
→ Built-in temperature & humidity sensor and external sensor (NTC)
→ Zone control: according to the nature of different room use and user habits, different temperatures are set to achieve independent constant temperature and humidity control with a single room as a unit
→ Air conditioning and floor heating lines are consistent with traditional temperature control panels, can be used directly for new installations & upgrades of old systems
Floor cooling system
→ For heat pump system, simultaneous control of top & ground radiation
→ Dry contact & Modbus 485, remote & voice control, APP timing & scene set control, temperature and humidity display
→ Three cooling modes (top cooling, floor cooling + top cooling, floor cooling)
→ Three heating modes (floor heating, floor heating & fan coil, fan coil)
Built-in temperature & humidity sensor and external sensor (NTC) panel with anti-condensation function
→ Zone control: according to the nature of the use of different rooms and user habits to set different temperatures to achieve independent constant temperature and humidity control with a single room as a unit
Heating system
→ For heat-fired boilers, wall-mounted stoves & heat pump heating systems
→ Temperature control panel with external temperature sensor, can be used as water temperature detection & temperature setting panel, both timing control & temperature control
→ Temperature control panel with built-in temperature and humidity sensor, can be used as single heating thermosta
→ Both local linkage and remote control functions, can be set through the APP timing, scene applications and other functions
→ Zone control: according to the nature of different room use and user habits, set different temperatures to achieve a single room as a unit, each room to achieve independent constant temperature
Secondary pump system
→ For heat pump system, simultaneous control of AC/DC fan coil and floor heating
→ DC fan with 0~10V automatic speed control and 5-speed manual speed control
→ Suitable for all mainstream DC fan brands on the market
→ Wired dry contact & Modbus 485, remote & voice control, APP timing & scene setting, temperature & humidity display
→ Water module linkage via indoor panel dry contact or 485 line, three sets of probes for temperature sensing, secondary pump linkage switch & host mode
→ Zone control: according to the nature of different room use and user habits to set different temperatures to a single room as a unit, to achieve independent constant temperature and humidity control
→ Air conditioning and floor heating line with the traditional temperature control panel, can be directly used for new installation & upgrade of the old system
Hot water circulation system
→ Suitable for hot water circulation pump control
→ App timer to run the hot water cycle before the daily water peak time, ensuring that the water is instantly hot when it is used
→ Hot water temperature control & time control
→ The hot water circulation pump runs intermittently during the cycle and supports customised pump start and stop times
→ External NTC for constant temperature circulation of the hot water tank within a set time
Heat pump+Water system
→ Centralised control of heat pump systems and hot water circulation pumps
→ Wired linkage of secondary systems
→ Storage tank temperature control with Modbus 485 for water temperature linkage
→ App timer to run the hot water cycle before the daily water peak hours to ensure instantaneous heating when water is used
→ The hot water circulation pump runs intermittently during the cycle and supports customised pump start and stop times
→ External NTC for constant temperature circulation of the hot water tank during the set time
Auxiliary heating (climate compensation)
→ For heat pump auxiliary heating systems, with simultaneous control of fan coil and floor heating
→ When the heating load is too high in cold climates, the wall-hung stove can be used as an auxiliary heat source to meet the heating demand of the system
→ Local linkage, one-touch central control and remote control, with timer and scene setting via APP
→ Zone control: according to the nature of the use of different rooms and user habits, set different temperatures to individual rooms as a unit, each room to achieve independent thermostat
→ One-touch switching of winter and summer modes at the end, from 485 mode to dry contact linkage for host-side mode switching
Two heat pump system
→ Simultaneous control of two heat pumps, load balancing control, save energy and extend the life of heat pump
→ Local linkage, one-key central control and remote control functions, timing and scenes can be set via APP
→ Zone control: according to the nature of different rooms and user habits, different temperatures can be set and each room can be used as a unit to achieve independent constant temperature